EXAMPLES OF IMPROPER CONSTRUCTION
Below are some image galleries where I reflect roofing and construction work from other contractors where clear issues are highlighted.
SIDEWALL FLASHING NOT PROPERLY INSTALLED
The following pictures show a sidewall flashing not properly installed, this roof is 10 years old and was new construction when installed. Manufacturer specs call for 1 step flashing per row of comp. The roof slope is only a 3/12 pitch which should have Ice & Water shield installed, best or 2 layers of 30lb underlayment, adequate but not my first choice for low slope. Anything 3/12 below is considered low slope and certain techniques or materials must be used to insure water tight integrity.
ROOFER MADE SKYLIGHT FLASHING
Roofer made skylight flashing, not even close to the proper way of installing the upper and lower saddles. Proper saddles are bent and soldered at a sheet metal shop. Relying on sealant is no way to make something watertight and is poor practice.